REDY UC Process WIT
REDY Process LAN/3G/4G Central Unit
The REDY Process Intelligent Local Units enable acquisition, equipment control and data transmission. They centralize all technical, energy and environmental data, control equipment optimally and restore information to different building actors (occupant, operator, manager...) to enable them to understand and optimize its operation. They are the intelligent orchestrators of various technical systems: heating, air conditioning, ventilation, ECS, lighting, renewable energies, storage, self-consumption, etc. Their modularity allows them to make the solution adaptable to all types of buildings and to easily upgrade facilities over time.
Features:
- - Processing power
- - Storage capacity
- - Integrated RJ45 LAN network card
- - Native WIFI
- - 3G and 4G modem
- - Expandable with various modules
REDY UC Monitor WIT
REDY Monitor LAN/3G/4G Central Unit
The REDY Monitor Intelligent Local Units enable data acquisition and transmission. They centralize all technical, energy and environmental data and provide information to different building actors (occupant, operator, manager...) to enable them to understand and optimize its operation. Domains: heating, air conditioning, ventilation, DHW, lighting, renewable energies, storage, self-consumption, etc. Their modularity allows them to make the solution adaptable to all types of buildings and to easily upgrade facilities over time.
Features:
- - Processing power
- - Storage capacity
- - Integrated RJ45 LAN network card
- - Native WIFI
- - 3G and 4G modem
PLUG I/O WIT
Input/Output Modules
The modules are installed on REDY bases and PLUG I/O bases. They enable data acquisition and equipment control.
PLUG I/O formats:
- PLUG 4.0.0.0 /4Di/ 5-48VDC/24VAC/
- PLUG 7.0.0.0 /7Di/ common GND/
- PLUG 4.0.0.0 /4Di/ 230V/
- PLUG 0.7.0.0 /7Do/ Optocoupled/100mA/
- PLUG 0.4.0.0 /4Do/ 0.5A - 48VDC/1A - 230V/
- PLUG 0.0.4.0 /4Ai/ 4...20mA/0-10V/Pt100/Pt1000/Ni1000/.../
- PLUG 0.0.2.2 /2Ai/ same as PLUG 0.0.4.0/2Ao/4...20mA/0-10V/
- PLUG 3.2.0.0 /3Di/ common GND/2Do/0.5A - 48VDC/1A - 230V/
PLUG COM RS232
RS232 Communication Module
The module is installed on PLUG I/O bases. It enables RS232 communication with all WIT controllers, as well as with equipment offering the following protocols:
- Modbus
- M-Bus
- ESPA
- EMI/UCP
- Text printer
PLUG COM RS485
RS485 Communication Module
The module is installed on PLUG I/O bases. It enables RS485 communication with all WIT controllers, as well as with equipment offering the following protocols:
- Modbus
- M-Bus
- ESPA
- EMI/UCP
- Text printer
Embases REDY WIT
Bases for UC REDY
The bases accommodate UC REDY units, as well as, depending on the model, several PLUG I/O modules. They are powered by 230V or 24VAC/DC. They include 1 RS232 communication port and 2 RS485 communication ports.
UC REDY base formats:
- P0: UC REDY only with its POWER supply module (230V or 24VAC/DC)
- P6: UC REDY + POWER module + 6 PLUG I/O
Embases PLUG I/O WIT
Bases for PLUG I/O
The bases accommodate 1 RS232 or RS485 communication module, as well as, depending on the model, several PLUG I/O modules. They are powered by 230V or 24VAC/DC or 12VDC.
PLUG I/O base formats:
- P1: 1 power supply module, 1 RS232 or RS485 communication module and 1 I/O module
- P2: 1 RS232 or RS485 communication module and 2 I/O modules
- P3: 1 power supply module, 1 RS232 or RS485 communication module and 2 I/O modules
- P4: 1 RS232 or RS485 communication module and 4 I/O modules
- P9: 1 power supply module, 1 RS232 or RS485 communication module and 9 I/O modules
Interfaces - Gateways
Protocol Gateways
Communication gateways for protocol conversion and system integration.
KNX - Modbus
- Reading and control of KNX equipment
- 9-30VDC or 24VAC
- DIN rail
LON - Modbus
- Reading and control of LON equipment
- 9-30VDC or 24VAC
- DIN rail
Supervision e@sy Pilot
Multi-workstation and Multi-site Supervision
Simple and User-friendly
The e@sy-pilot supervision offers total control of buildings and technical installations through simple, user-friendly interfaces, both locally and remotely.
Multi-workstation Web Access
Because supervision can be the role of several people, e@sy-pilot supervision allows multiple users to access it simultaneously from multiple computers, without software and without additional license per client workstation. A simple web browser is sufficient for its configuration and use.
Open and Communicative
The e@sy-pilot supervision uses all current communication media: TCP/IP (LAN and Internet), GSM/GPRS, PSTN, wireless networks (Wi-Fi, 868Mhz, EnOcean, etc.) and has the main M2M protocols: WOP, TRSII, Modbus/J-Bus, BACnet, M-Bus, EtherNet/IP, SMA, etc.
Storage Capacity and Data Security
The SQL database on which e@sy-pilot supervision is based offers sufficient storage capacity to operate and secure data from several hundred sites. The SQL database also allows e@sy-pilot to interface with other applications such as ERP systems.
Synoptics
The e@sy-pilot supervision allows the creation of synoptic screens for visualization and control of sites in the form of fixed or animated objects. For each point, it is possible to have specific animations defined in a style library. It is thus possible to modify:
- fonts, their size and color.
- background, frame, and shadow colors.
- justifications.
- transparency.
- style effects between blinking, erasure, color complement, animated frames.
Images are extracted from an image library integrated into e@sy-pilot. However, it is possible to create your own library to meet specific needs.
Graphics
A tool for configuring graphic preparations (curve plotting) is integrated into the supervision. It is thus possible to create any association of recordings (history of analog inputs or digital inputs), to visualize them on the same view. The recordings displayed on the screen can be printed on a color printer or exported to files. For each graphic preparation, it is possible:
- to choose the color of each recording.
- to select time scales (from minute to year)
- to add a visualization grid.
- to place markers in the form of thresholds.
And more...
- Various types of action planning
- Site status list
- Event log
- Ongoing log
- Variable acquisition from 500 to unlimited
- Number of communicating sites from 5 to unlimited